1700.C vacuum atmosphere hydrogen furnace uses 1800 molybdenum wire as heating element, adopts three-layer shell structure and Japan Shimaden’s 40-stage program temperature control system, phase shift trigger, thyristor control, and the furnace adopts Japanese imported alumina polycrystalline fiber material , The inner and outer chambers are equipped with an air-cooled system, which can quickly raise and lower the temperature. The shell is sealed as a whole. The cover and the furnace door are sealed with high-temperature silica gel O-rings. The furnace door is equipped with a water-cooling system. The gas enters from the back chamber after passing through the flowmeter, and is discharged from the outlet valve at the furnace door after passing through the furnace. The furnace can be sintered under vacuum. The furnace has a KF25 quick-connect interface on the side, which can be connected to a vacuum pump. The vacuum pump outlet is equipped with a smoke filter and the exhaust port is equipped with a dust filter; and is equipped with a bellows, a vacuum pump (connected Furnace and vacuum metal tube), KF25 quick clamping sleeve, vacuum baffle valve, imported resistance vacuum gauge, etc. The minimum vacuum of the furnace is less than 10Pa, and hydrogen, argon, nitrogen, oxygen, carbon monoxide, ammonia decomposition gas can also be passed The furnace has the advantages of small size, balanced temperature field, low surface temperature, fast temperature rise and fall, and energy saving. It is an ideal product for universities, scientific research institutes, and industrial and mining enterprises for atmosphere protection sintering and atmosphere reduction.
Max. Temperature | 1700 degree |
---|---|
Working Temperature (Max.) | 1650 -1700 degree |
Temperature Controller | Japan Brand SHIMADEN FP93 |
Furnace produce process:
Metal plate Cutting -Bending -Welding- Polishing – Powder coating- chamber board Carrving – Electrical module assembly – Whole machine assembly – Heating Test – Packing .
1700.C vacuum atmosphere hydrogen furnace uses 1800 molybdenum wire as heating element, adopts three-layer shell structure and Japan Shimaden’s 40-stage program temperature control system, phase shift trigger, thyristor control, and the furnace adopts Japanese imported alumina polycrystalline fiber material , The inner and outer chambers are equipped with an air-cooled system, which can quickly raise and lower the temperature. The shell is sealed as a whole. The cover and the furnace door are sealed with high-temperature silica gel O-rings. The furnace door is equipped with a water-cooling system. The gas enters from the back chamber after passing through the flowmeter, and is discharged from the outlet valve at the furnace door after passing through the furnace. The furnace can be sintered under vacuum. The furnace has a KF25 quick-connect interface on the side, which can be connected to a vacuum pump. The vacuum pump outlet is equipped with a smoke filter and the exhaust port is equipped with a dust filter; and is equipped with a bellows, a vacuum pump (connected Furnace and vacuum metal tube), KF25 quick clamping sleeve, vacuum baffle valve, imported resistance vacuum gauge, etc. The minimum vacuum of the furnace is less than 10Pa, and hydrogen, argon, nitrogen, oxygen, carbon monoxide, ammonia decomposition gas can also be passed The furnace has the advantages of small size, balanced temperature field, low surface temperature, fast temperature rise and fall, and energy saving. It is an ideal product for universities, scientific research institutes, and industrial and mining enterprises for atmosphere protection sintering and atmosphere reduction.
The furnace is sealed with glove box technology, and the sealing effect is very good. It can be used under vacuum or atmosphere. When vacuuming and maintaining pressure, it can ensure that the pressure gauge pointer does not deflect within 5 hours.
Item No.: | VAF1700-H2-I | VAF1700-H2-II | VAF1700-H2-III |
---|---|---|---|
Rated Power: | 4KW | 8KW | 16KW |
Chamber size (mm)(DXWXH): | 160X150X150mm | 300X200X200 | 400X300X300 |
Overall Dimension (WXDXH)mm: | 550X470X810 | 600X 610X860 | 700X 710X1355 |
Rated Voltage: | 220V , 1 Phase. | 220V , 1 Phase. | 380V, 3 phase |
Heating Elements: | 1800 molybdenum wire for Hydrogen Furnace | ||
Control Mode : | FP93 temperature control instrument (Japan Shimaden ) 1. The 40-segment program temperature control can be divided into 4/2/1 groups of programs. If divided into 4 groups of programs, each program has 10 segments; 2. 6 groups of PID control, one group of PID can be used for low, medium and high temperature, so that each temperature section can be controlled very accurately. 3. With over-temperature protection and broken couple protection, the heating circuit of the electric furnace is automatically cut off when the temperature is over or broken. (When the temperature of the electric furnace exceeds 1720 degrees or the thermocouple is blown out, the AC relay on the main circuit will be automatically disconnected, and the main circuit will be disconnected. , The ON light on the panel goes out and the OFF light is on, limited protection of the electric furnace). 4. The instrument is available in Fahrenheit F and Celsius C 5. With 485 communication interface (standard configuration when purchasing software) 6. With automatic shutdown function 7. It can store multiple sets of programs, and can be recalled arbitrarily when in use. 8. With power-off protection function, that is, when the furnace is powered on after power-off, the program does not start from the starting temperature, but from the power-off. 9. There are displays on the meter that the output power, the number of program execution stages and execution time, and the program is in the heating, constant temperature, and cooling state. 10. The meter has a skip function: the meter can skip this step and directly execute the next step. 11. The instrument has the function of temperature self-tuning. |
||
Chamber Materials: | 1800 type alumina polycrystalline fiber (alumina content above 95%) imported from Japan | ||
Temperature Control Mode : | Intelligent PID | ||
Control Accuracy: | ±1 ℃ | ||
Thermocouple Type: | B Type | ||
Trigger: | Phase shift trigger (with soft start and current limit function) Current limiting function: No matter how you adjust the heating time, the secondary current of our electric furnace after passing through the transformer is limited to less than 160A, which effectively protects the equipment. No matter how you operate, the equipment will not be burned out. If the current is greater than the set current 1.5 When the time is over, the trigger will automatically stop triggering to protect the equipment. Soft start function: The current will increase slowly when starting up, and the impact on the heating element is small, which is conducive to the extension of the life of the heating element |
||
Thyristor: | German SEMIKRON 106/16E | ||
Heating rate: | ≤20℃/ Min, suggest ≤10℃/ Min. | ||
Vacuum Pump(optional parts): | VRD-16 | ||
Chiller | The flow rate is 16L/min, with over-temperature, under-temperature alarm and under-voltage alarm functions. | ||
Explosion-proof valve (optional): | Electronic type can set explosion-proof pressure according to needs | ||
Surface Temperature: | ≤45℃ | ||
Software control system: | Equipped with communication interface and software, the various parameters of the furnace can be directly controlled by the computer, and the PV and SV temperature values on the furnace and the operation of the instrument can be observed from the computer. The actual heating curve of the furnace will be drawn in real time by the computer. Save the temperature data at each moment and recall it at any time. (Free software, communication interface, data cable) | ||
Open cover protection system: | equipped with a travel switch, which will automatically cut off the power when the furnace cover is opened, which effectively guarantees the user’s safety protection system | ||
Sealing System: | The furnace top cover and furnace door (other places have been welded) are both extruded and sealed with silicone O-rings, which are convenient to remove and can be removed repeatedly. The air tightness is good, and it can ensure that the pointer of the pressure gauge does not deflect for 8 hours. | ||
Leakage protection function: | Equipped with a leakage air switch, which automatically cuts off the power when the furnace body leaks to ensure the safety of use | ||
Outlet valve : | The gas outlet valve is a one-way valve, and the gas can only flow out but not flow back |
This hydrogen atmosphere furnace with molybdenum wire as the heating element cannot be heated in air or oxygen. The following table shows the maximum heating temperature of the atmosphere furnace in the following gases
(Hydrogen atmosphere furnace with molybdenum wire as heating element can only be heated in the following atmosphere):
Atmosphere | Maximum operating temperature in various atmospheres |
---|---|
He, Ar , Ne | 1700 |
H2 (75%), N2 (25%) mixed gas | 1700 |
H2 | 1700 |
He, Ar, Ne and H2 Mixed gas, H2 can be any content | 1700 |
Warranty:One year warranty, lifetime technical support;
Note: Consumable parts such as heating elements, sample crucibles, etc. are not covered by the warranty, and damage caused by the use of corrosive gases or materials is not covered by the warranty.
Operating Notes:
It is forbidden to use the furnace in air or oxygen environment
If you use hydrogen, please pay special attention to the following points:
1. H2 is a flammable and explosive gas. Its combustion temperature is 400℃. It will explode when its mixing ratio with air reaches 4.0%-74.2%. Therefore, safety measures must be taken when using hydrogen.
2. The maximum pressure in the furnace chamber is 0.02Mpa, so when gas is introduced into the furnace chamber, a pressure reducing valve must be installed on the gas cylinder;
3. Before entering hydrogen, the furnace must be cleaned with inert gas.
4. The air pressure inside the furnace should always be kept between 0.01-0.02 Mpa during use to prevent air from flowing back into the furnace and causing an explosion.
5. The room where the equipment is placed must be well ventilated.
6. In order to keep the air pressure in the furnace relatively stable during the heating process, we recommend that the heating rate of the equipment is less than 10°C/min.
7. This furnace cannot be put into toxic and corrosive gas, otherwise it will damage the furnace and heating elements
Detailed description:
Item: | Qty |
---|---|
Furnace Body: | 1 Set |
Themocouple : | 1pc, Already installed |
Alumina Crucible: | 1pc |
Crucible tongs: | 1PC |
Door block: | 1pc |
Alumina padding brick: | 1pc |
High temperature gloves: | 1 pair |
Vacuum pump: | VRD-16 1pc |
Vacuum pump filter: | 1pc |
Vacuum flapper valve: | 1pc |
Bellows: | 1pc |
Float Flowmeter: | 1pc |
Smoke filter: | 1pc |
Digital display pressure transmitter: (Optional) | 1pc |
Explosion-proof solenoid valve : (Optional) | 1pc |
KF clamps: | 1pc |
KF Tee: | 1pc |
Resistance vacuum gauge: | 1pc |
COM to 485 communication interface (optional): | 1pc |
User Manual : | 1PC |
OPTIONAL SYSTEM / DEVICE :
We will contact you within 1 working day, please pay attention to the email with the suffix “@yuhongfurnace.com”.