This tube furnace adopts double-layer shell structure and electronic temperature control instrument, can carry out 30-segment temperature control, phase shift trigger, and thyristor control. The furnace adopts oxidation Aluminum polycrystalline fiber material has the advantages of balanced temperature field, low surface temperature, fast temperature rise and fall, and energy saving. It is an ideal product for universities, scientific research institutes, and industrial and mining enterprises for high-temperature atmosphere sintering, atmosphere reduction, CVD experiments, and vacuum annealing.
Max. Temperature | 1200 degree |
---|---|
Working Temperature (Max.) | 1100 degree |
Furnace produce process:
Metal plate Cutting -Bending -Welding- Polishing – Powder coating- chamber board Carrving – Electrical module assembly – Whole machine assembly – Heating Test – Packing .
The CVD system consists of a gas supply system + a tube furnace + a gas extraction system. The maximum temperature can reach 1200 degrees, 1400 degrees, 1600 degrees, and 1700 degrees. The heating zone can be single temperature zone, dual temperature zone, three temperature zone, etc., and the ultimate vacuum It can reach 10-3Pa. The gas supply system can be a proton flow meter or a float flow meter with flow adjustment. The number of gas mixing channels can be 2 channels, 3 channels, 4 channels, and 5 channels.
This CVD system is composed of a 3-way gas supply system + TL1200 hydrogen tube furnace + low vacuum system.
Item No.: | TF1200-H2-I | TF1200-H2-II | TF1200-H2-III | TF1200-H2-Ⅳ |
---|---|---|---|---|
Rated Power: | 3.5KW | 3.5KW | 3.5KW | 5KW |
Heating Zone size (mm)(Dia. x L): | OD60 x 440mm | OD80 x 440mm | OD100 x 440mm | OD150 x 440mm |
Constant temperature zone : (mm) | 150 | 150 | 150 | 150 |
Furnace tube size OD (mm): | High purity quartz tube: OD 60/80/100/150*1000mm (tube diameter is optional) A furnace plug is placed at each end. The furnace plug can block the heat radiation in the center of the furnace tube and must be placed in the correct position of the furnace before heating. |
|||
Overall Dimension (WXDXH)mm: | 1700X800X1500 | 1700X800X1500 | 1700X800X1500 | 1700X800X1500 |
Rated Voltage: | 220V , 1 Phase. | 220V , 1 Phase. | 220V , 1 Phase. | 220V , 1 Phase. |
Heating Elements: | Domestic high quality resistance wire; Swedish Kanthal A1 imported resistance wire is optional; |
|||
Control Mode : | 30-segment program temperature control: 1. The 30-segment program temperature control can only be adjusted by PID. 2. With over-temperature protection and broken couple protection, the heating circuit of the electric furnace is automatically cut off when over-temperature or broken couple; (When the temperature of the electric furnace exceeds 1200 degrees or the thermocouple is blown, the AC relay on the main circuit will be automatically disconnected, the main circuit will be disconnected, the ON light on the panel will go out, and the OFF light will be on, limited protection of the electric furnace) 3. With 485 communication interface (standard configuration when purchasing software) 4. With power-off protection function, that is, when the furnace is powered on after power-off, the program does not start from the initial temperature rise, but the furnace temperature starts to rise when the power is off. 5. The instrument has the function of temperature self-tuning. |
|||
Chamber Materials: | 1. High-quality and high-purity alumina polycrystalline fiber curing furnace formed by vacuum suction filtration. 2. Using Japanese technology to form. 3. The spacing and pitch of the resistance wires in the furnace are all arranged according to the best thermal technology in Japan, and the temperature field is simulated by thermal software. |
|||
Temperature Control Mode : | Intelligent PID | |||
Control Accuracy: | ±1 ℃ | |||
Thermocouple Type: | K Type | |||
Trigger: | Phase shift trigger | |||
Heating rate: | ≤30℃/ Min, suggest ≤15℃/ Min. | |||
Temperature field curve | Furnace at 1000.C : | |||
Temperature calibration (optional): | Regular temperature calibration of the tube furnace can maintain the accuracy and uniformity of the furnace temperature. You can purchase a set of simple calibration tools to assist you in this task. A complete calibration kit includes standard thermocouples, temperature calibrators, and compensation wires. | |||
Valves and flanges: | ||||
Surface Temperature: | ≤45℃ | |||
Over Temperature Protection: | Yes | |||
Overcurrent Protection: | Yes | |||
Broken Couple Protection: | Yes | |||
Explosion-proof system: | The explosion-proof system consists of a pressure sensor and an explosion-proof valve. The pressure sensor can set an alarm pressure on the pressure control gauge. When the pressure in the furnace tube is greater than or equal to the set alarm pressure, the explosion-proof solenoid valve will automatically start and release the excess gas in the furnace tube. The explosion-proof solenoid valve is composed of two check valves with opposite directions, which can be closed well in vacuum or atmosphere, without air leakage and no backflow. |
|||
Hydrogen detector: | The hydrogen gas detector is a safety instrument that can detect the flammability and explosiveness of hydrogen through an imported catalytic combustion sensor. It has the characteristics of explosion-proof and dust-proof, and can be widely used in places where hydrogen is stored, used and stored in petroleum, chemical industry, metallurgy, coal mines, etc. |
Gas supply system Main parameters:
Mass flowmeter: | Rate Range and gas: | 5, 10, 20, 30, 50, 100, 200, 300, 500SCCM, 1, 2, 3, 5, 10SLM (you can arbitrarily select the above range and the type of gas) |
Max. pressure: | 3MP | |
Flow control accuracy: | ±1.0%F.S | |
Max. working pressure: | 0.3MPa | |
linear: | ±0.5%F.S. | |
Repeat accuracy: | ±0.2% F.S | |
Gas Channels Qty: | 1, 2, 3, 4, 5, 6, 7, 8 channels (optional) | |
Connector type: | Double ferrule stainless steel joint | |
System working pressure range: | 0.1~0.5 MPa | |
Working temperature: | 5-45℃ | |
Pressure vacuum gauge: | -0.1~0.15MPa | |
Static mixing chamber: | Dia50 X 400MM | |
Port size: | Dia6 / 1/4” |
VS-0.1 Air Extraction System: Option 1 or 2
Power: | 220V | |
Dimensions: | 650X650X600 / 650X650X300 | |
Bellows: | KF25X1000mm | |
Max. Vacuum : | 10 -1Pa | |
Vacuum flapper valve: | KF25 | #colspan# |
VRD-8 vacuum pump (Option I): | Model: | VRD-8 |
Ultimate partial pressure: | 5X10-2 Pa | |
Intake and exhaust port: | KF25 | |
Motor speed: | 1440RPM | |
Pumping rate: | 2.2L/S | |
Motor Power | 0.4kw | |
Preiffer ACP15 oil-free multi-stage Roots pump (Option II): | Model: | ACP15 |
power supply: | AC100-240 50/60HZ | |
Power: | 450w | |
weight: | 25kg | |
Maximum helium leak rate: | 5 · 10-8 Pa m3/s | |
Pumping rate: | 14 m3/h | |
Ultimate pressure: | 0.02Torr | |
Inlet and exhaust interface: | KF25 | |
Vacuum measurement: Resistance vacuum gauge (Option I): | Model: | ZDR-1 |
Power: | 25w | |
Vacuum measurement range: | 0.1-10 5 Pa | |
Resistance silicon: | ZJ-52T | |
Vacuum measurement: Sweden (INFICON) Pirani Ceramic Capacitance Vacuum Gauge (Option II) | Model: | PCG554 |
Input voltage: | 24V 1A DC (with 220V transformer) | |
Vacuum gauge interface: | KF16 | |
Digital Display: | Digital display (screen size is 20x14mm), and its data display unit is torr | |
Product Size: | 46mm×28mm×126mm ( L x W x H) | |
weight: | 5 lbs | |
Detection gas: | It can detect various gases, including mixed gases, with accurate measurement and good repeatability. | |
Whether it is anticorrosive: | anticorrosive | |
Response time: | ≤30ms | |
Measuring range: | 3.8×10-5 -1125 Torr. |
Molecular pump unit (optional):
Unit input voltage: | 380V /220V | |
Bellows: | KF40X1000 | |
Vacuum flapper valve | KF40 | |
Box Size: | 600X600X600 | |
Molecular pump (Option I) | Molecular pump model: | FJ620 |
Input voltage: | 380V | |
Molecular pump inlet flange: | DN160 | |
Molecular pump pumping rate L/S (to air): | 600 | |
Ultimate pressure of molecular pump (Pa): | 6×10-7 | |
Cooling method: | water cooling | |
Cooling water pressure (MPa): | 0.1-0.2 | |
Cooling water temperature: | <25℃ | |
Ambient temperature: | 0~40℃ | |
Recommended starting pressure: | <100pa | |
Molecular pump fore vacuum TRP-24 (FJ620 molecular pump must be equipped with previous stage pump): | Power: | 0.75kw |
Voltage: | 380V | |
Rotating speed: | 1450rpm | |
Inlet diameter: | KF25/KF40 | |
Pumping rate of front machine pump (L/S): | 6 | |
Ultimate pressure: | 4X10 -2Pa | |
German Pfeiffer vacuum pump (Option II) | Voltage: | 220V |
Power: | 110W | |
Air extraction interface: | KF40 | |
weight: | 150KG | |
Front pump pumping speed: | 0.9m 3/ h | |
Pumping rate (N2): | 33L/S | |
Compound vacuum gauge: | Compound vacuum gauge model: | ZDF |
Power supply: | 220V 55W | |
control precision: | ± 1% | |
Vacuum gauge measuring range: | 10-5 -10 5 Pa |
Warranty period: One year warranty and lifetime technical support.
Note: 1. Consumable parts such as heating elements, thermocouple , quartz tubes, sample crucibles, etc. are not within the warranty period.
2. Damage caused by the use of corrosive gas and acid gas is not covered by the warranty.
Operating Notes:
1. The air pressure in the furnace tube should not be higher than 0.02MPa;
2. Due to the high internal pressure of the gas cylinder, a pressure reducing valve must be installed on the gas cylinder when gas is introduced into the furnace tube. In order to ensure safety, it is recommended that the pressure be lower than 0.02MPa;
3. The gas flow into the furnace tube must be less than 200SCCM to avoid the impact of cold air flow on the hot furnace tube;
4. For the sample heating experiment, it is not recommended to close the exhaust valve and intake valve at the flange end of the furnace tube. If you need to close the gas valve to heat the sample, you need to pay attention to the indication of the pressure gauge at all times; if the pressure indication is greater than 0.02MPa, you must open the exhaust valve immediately to prevent accidents (such as furnace tube rupture, flange flying, etc.) .
The tube furnace uses Domestic high-quality resistance wire / imported resistance wire Sweden (kanthal) as heating element, adopts double-layer shell structure and electronic temperature control instrument, can carry out 30-segment temperature control, phase shift trigger, and thyristor control. The furnace adopts oxidation Aluminum polycrystalline fiber material has the advantages of balanced temperature field, low surface temperature, fast temperature rise and fall, and energy saving. It is an ideal product for universities, scientific research institutes, and industrial and mining enterprises for high-temperature atmosphere sintering, atmosphere reduction, CVD experiments, and vacuum annealing.
Detailed description:
Item: | Qty |
---|---|
Furnace Body: | 1 Set |
Quartz tube : | 1pc |
Stainless steel flange: | 1set |
Themocouple : | K type 1pc, Already installed |
Stainless steel hook: | 1pc |
Tube block | 1pc |
Alumina Crucible: | 1pc |
flange support: | 1pc |
High temperature gloves: | 1 pair |
Gas supply system: | 1 set |
VS-0.1 air extraction system: | 1 set |
KF clamps: | 4pc |
Bellows: | 1pc |
Vacuum flapper valve: | 1pc |
Cylinder connector (N represents the number of lines): | N pc |
Valve connector: | 2pc |
Teflon tube (N represents the number of lines): | Nx5 |
User Manual : | 1PC |