The resistance wire of this box-type hydrogen atmosphere furnace is the heating element. It adopts a double-layer shell structure and a 30-segment program temperature control system, phase-shifting trigger, and thyristor control. The furnace adopts alumina polycrystalline fiber material, and the double-layer furnace shell is used. Equipped with an air-cooled system, which can quickly rise and fall in temperature. The shell is sealed as a whole, the cover is sealed with silica gel mud, the furnace door is made of silica gel pads and is equipped with a water cooling system. There are burners at the gas port and the gas outlet, which can be pre-evacuated and can pass hydrogen, argon, nitrogen, oxygen, carbon monoxide, ammonia decomposition gas and other gases. The furnace has a balanced temperature field, low surface temperature, and fast rise and fall temperature. Energy saving and other advantages, it is an ideal product for universities, scientific research institutes, and industrial and mining enterprises for atmosphere protection sintering and atmosphere reduction.
Max. Temperature | 1200 degree |
---|---|
Working Temperature (Max.) | 1100 degree |
Furnace produce process:
Metal plate Cutting -Bending -Welding- Polishing – Powder coating- chamber board Carrving – Electrical module assembly – Whole machine assembly – Heating Test – Packing .
Item No.: | AF1200-H2-II | AF1200-H2-Ⅳ | AF1200-H2-V |
---|---|---|---|
Rated Power: | 4KW | 9KW | 16KW |
Chamber size (mm)(DXWXH): | 300X200X200 | 400X300X300 | 500X400X400 |
Overall Dimension (WXDXH)mm: | 520X610X765 | 700X 700X880 | 810X850X1060 |
Rated Voltage: | 220V , 1 Phase. | 380V, 3 phase | 380V, 3 phase |
Heating Elements: | Domestic high quality resistance wire; Swedish Kanthal A1 imported resistance wire is optional; |
||
Control Mode : | 30-segment program temperature control: 1. The 30-segment program temperature control can only be adjusted by PID. 2. With over-temperature protection and broken couple protection, the heating circuit of the electric furnace is automatically cut off when over-temperature or broken couple; (When the temperature of the electric furnace exceeds 1200 degrees or the thermocouple is blown, the AC relay on the main circuit will be automatically disconnected, the main circuit will be disconnected, the ON light on the panel will go out, and the OFF light will be on, limited protection of the electric furnace) 3. With 485 communication interface (standard configuration when purchasing software) 4. With power-off protection function, that is, when the furnace is powered on after power-off, the program does not start from the initial temperature rise, but the furnace temperature starts to rise when the power is off. 5. The instrument has the function of temperature self-tuning. |
||
Chamber Materials: | 1. High-quality and high-purity alumina polycrystalline fiber curing furnace formed by vacuum suction filtration. 2. Using Japanese technology to form. 3. The spacing and pitch of the resistance wires in the furnace are all arranged according to the best thermal technology in Japan, and the temperature field is simulated by thermal software 4.Adopt 4-sided heating (left, right, up, down, four sides), the temperature field is more balanced |
||
Temperature Control Mode : | Intelligent PID | ||
Control Accuracy: | ±1 ℃ | ||
Thermocouple Type: | K Type | ||
Trigger: | Phase shift trigger | ||
Heating rate: | ≤20℃/ Min, suggest ≤15℃/ Min. | ||
Safety protection system: | Equipped with an air switch, when the current exceeds the rated current of the air switch, the empty meeting will automatically open, effectively protecting the electric furnace | ||
Door opening protection system: | Equipped with a travel switch, the furnace door is opened and taken, and the main furnace of the electric furnace will automatically power off | ||
Surface Temperature: | ≤45℃ | ||
Over Temperature Protection: | Yes | ||
Overcurrent Protection: | Yes | ||
Broken Couple Protection: | Yes | ||
Warranty: | One year warranty, lifetime technical support; Note: Consumable parts such as heating elements, sample crucibles, etc. are not covered by the warranty, and damage caused by the use of corrosive gases or materials is not covered by the warranty. |
Warranty:One year warranty, lifetime technical support;
Note: Consumable parts such as heating elements, sample crucibles, etc. are not covered by the warranty, and damage caused by the use of corrosive gases or materials is not covered by the warranty.
Operating Notes:
1. For safety, please put the stove in a ventilated place.
2. In order to improve the service life of the furnace, we recommend that the heating rate should not exceed 10°C/min. The cooling rate does not exceed 5°C/min.
3. The furnace has no vacuum tightness, and it is forbidden to pass toxic or explosive gases
4. It is forbidden to put the materials directly on the bricks at the bottom of the furnace, please put the materials in the special crucible.
5. When heating, the material and crucible should not touch the heating element and thermocouple
6. If not used for a long time, please bake the oven before using it again.
Detailed description:
Item: | Qty |
---|---|
Furnace Body: | 1 Set |
Themocouple : | K type 1pc, Already installed |
Alumina Crucible: | 1pc |
Crucible tongs: | 1PC |
Alumina padding brick: | 1pc |
High temperature gloves: | 1 pair |
User Manual : | 1PC |
OPTIONAL ACCESSORIES: